Error number 7704

<< 点击显示目录 >>

主页  mappVision帮助助手 > 机器视觉帮助 > mapp Vision  > 诊断 > 状态编号 > AS 错误编号
 >

Error number 7704

短文

项目路径太长,无法使用 mapp Vision。

错误描述

Automation Studio 项目的临时路径过长,导致无法为 mapp Vision HMI 应用程序创建可视化。其他构建工件的生成也会受到影响。

另请参阅常规条件。默认情况下,临时文件的路径位于项目文件夹中。

纠错建议

通过缩短项目名称或项目所在路径来缩短项目路径。对于 mapp Vision 人机界面可视化的生成,缩短视觉组件的名称也有帮助。还可以在项目外配置一个临时文件夹,详情请参见常规项目设置。


Short text

The project path is too long, mapp Vision cannot be used.

Error description

The temp path of the Automation Studio project is too long, this makes it impossible to create the visualization for the mapp Vision HMI application. The generation of other build artefacts can also be affected.

 

See also General conditions. By default, the path for temporary files is located in the project folder.

Suggestion for error correction

Shortening the path of the project by shortening the project name or the path where the project lies. For the generation of the mapp Vision HMI visualization shortening the names of vision components could also help. It is also possible to configure a temporary folder outside the project, for more info see General project settings.